IEC60529 50W 0.3MPa 10L/Min Oxygen Index Tester
![]() |
Oxygen Index Tester Application: Applicable to the determination of the burning properties of materials such as plastics, rubbers, fibers, foams, films, films, and textiles Technical parameters: The use of imported oxygen sensor, digital display oxygen concentration without calculation, higher accuracy and accuracy, range 0-100% Digital resolution ±0.1% machine measurement accuracy 0.4 Flow adjustment range 0-10L/min......
Shanghai Glomro Industrial Co., Ltd.
|
Burning Limited Oxygen Index Tester Foam Limiting Textile or Plastic Standard GB/T5454 Laboratory
![]() |
... when it has just been able to support its combustion. The index is an index of the burning behavior of the material. The limit oxygen index tester can be used to test the material's limit oxygen index (LOI) to determine the degree of difficulty in the...
Suzhou Yangyi Vouch Testing technology Co.,Ltd
|
Flammability Testing Equipment Digital Oxygen Index Tester
![]() |
... and accuracy, the range of 0- 100% 2.Digital resolution: ± 0.1% 3.Machine measurement accuracy: 0.4 level 4.Flow adjustment range: 0-10L / min (60-600L / h) 5.Response time: <5S 6.Quartz glass tube: diameter ≥ 75 mm high 300mm 7.Gas flow ......
SKYLINE INSTRUMENTS CO.,LTD
|
Automatic Mass Flow Temperature Limited Oxygen Index Tester Simple / Compact Design
![]() |
... combustion. This equipment's the oxygen analyser is adapted Paramagnetic Type which has a precise, long life, less error rate and high reliability. TOI (Temperature Oxygen Index Tester) measures temperature index of specimen by heated mixing gases on...
DONGGUAN YUYANG INSTRUMENT CO., LTD
|
Oxygen Index Apparatus / Limiting Oxygen Index/ Limitation Oxygen Index Tester
![]() |
Oxygen Index Apparatus / Limiting Oxygen Index/ Limitation Oxygen Index Tester Contact: Mandy Skype: +86 155 8413 3985 WhatsApp:+86 155 8413 3985 Technical parameters Name Oxygen Index Tester Combustion tube inner diameter 100mm High combustion tube 450mm Flowmeter accuracy 2.5 grade Pressure gauge accuracy 2.5 grade Gas source GB3863 prescribed oxygen......
Shanghai Taist Industrial Co., Ltd
|
LOI-A Automatic Type Limiting Oxygen Index Tester
![]() |
...Oxygen Index Tester -- Model LOI-A Introduction: The oxygen index tester is designed to test combustibility by oxygen concentration, letting user know minimum oxygen concentration as necessary for combustion. The working principle is: Place the specimen into the testing chimney, filling with oxygen and nitrogen into the chimney, ignite the specimen, then measure the min concentration of oxygen......
Delta Technology (Chongqing) Co., Ltd.
|
HH61037 GB2406-2009 Wire Testing Equipment , Digital - Readout Oxygen Index Tester
![]() |
...burning. Polymer OI value is the min oxygen volume percent of the required oxygen and nitrogen gas mixture in the process of this material is able to be kept burning for 50 mm or 3 minutes once being ignited. With simple structure, easy to ......
Dongguan HOOHA Electrical Equipment Company Limited
|
Industrial Wire Testing Equipment Digital Readout Oxygen Index Tester GB2406-2009
![]() |
...burning. Polymer OI value is the min oxygen volume percent of the required oxygen and nitrogen gas mixture in the process of this material is able to be kept burning for 50 mm or 3 minutes once being ignited. With simple structure, easy to ......
Dongguan HOOHA Electrical Machinery Company Limited
|
ASTM D 2863 Plastics Rubber Oxygen Index Tester
![]() |
Oxygen Index Tester Description: Oxygen Index Tester is a tester used to measure the combustion performance of various textiles including woven, knitted, non-woven fabrics, plastics, rubber, paper, etc. Technical Parameters Model HD-R908 Flow adjustment range 0-20L/min......
Dongguan Haida Equipment Co.,LTD
|
ASTM D 2863 Plastics Rubber Oxygen Index Tester
![]() |
Oxygen Index Tester Description: Oxygen Index Tester is a tester used to measure the combustion performance of various textiles including woven, knitted, non-woven fabrics, plastics, rubber, paper, etc. Technical Parameters Model HD-R908 Flow adjustment range 0-20L/min......
Hai Da Labtester
|