| Sign In | Join Free | My polstate.com |
|
| Categories | Digital Flow Meter |
|---|---|
| Brand Name: | E+H |
| Model Number: | 8I1B |
| Place of Origin: | China |
| MOQ: | 1 pc |
| Price: | USD 600 |
| Payment Terms: | T/T |
| Supply Ability: | 100 pc |
| Delivery Time: | 7-14 days |
| Supply Voltage: | 10-30 VDC |
| Measuring Principle: | Absolute and gauge pressure |
| Process Connection: | 1/2" NPT |
| Mounting Type: | Threaded |
| Electrical Connection: | M12x1 |
| Reference Accuracy: | Standard: 0.05% Platinum: up to 0.025% |
| Output Signal: | 4-20 mA |
| Mounting Method: | DIN rail or wall mount |
| Protocol: | HART/RS485 |
| Temperature Range: | -40 to 185°F |
| Range: | 0-10,000 psi |
| Wetted Parts Material: | Stainless Steel |
| Material: | Stainless steel |
| Communication Protocol: | HART |
| Operating Temperature: | -20 to 85 degrees Celsius |
| Company Info. |
| Xi'an Xiyi Central Control Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
What is the Promass I 100
The Promass I 100 is a high-performance Coriolis mass flowmeter designed for industrial applications, offering measurements of mass flow, density, and temperature, with optional viscosity measurement.
It is part of the Endress+Hauser “Promass I” line, featuring a straight single-tube sensor design and very compact transmitter housing.
Measuring principle
Key Technical Features & Specifications
Here are some of its important characteristics:
Feature | Details |
Flow variables measured | Mass flow, density, temperature; optional viscosity. |
Sensor design | Straight single-tube design; “easy cleanable”. |
Tube material / wetted parts | Titanium for measuring tube; other parts in stainless steel or coating depending on version. |
Size range (nominal diameter) | DN 8 to DN 80 (≈ 3/8″ to 3″). |
Accuracy | • Liquids: about ±0.1 % for mass & volume flow; <-- density
accuracy in liquid ~ ±0.0005 g/cm³. |
Temperature / Pressure ranges | Medium temperature: from −50 °C up to approx +150 °C. |
Environmental / Protection | High ingress protection (IP69K in many versions). Robust transmitter housing. |
Installation | “Full-bore” design to minimize pressure drop. As its straight tube, less demanding for inlet/outlet runs compared to bent-tube designs. |
Outputs / Communication | Multiple typical industrial outputs: analog (4-20 mA with HART), digital protocols (Modbus RS-485, PROFIBUS, PROFINET, etc.), pulse/frequency/switch outputs. |
Additional features | Integrated web server for local configuration, diagnostics. “Heartbeat Technology” for verification and monitoring. |
Advantages
Limitations / Considerations
Typical Applications
The Promass I 100 is suitable for many industrial sectors, especially where accurate mass flow + density + temperature are needed, such as:
|