Sign In | Join Free | My polstate.com
polstate.com
Products
Search by Category
Home > Digital Camera >

Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field

Categories Digital Fundus Camera
Brand Name: SYSEYE
Model Number: RetiCam 3100
Certification: FDA
Place of Origin: China
MOQ: 1
Price: $12,000.00-$13,000.00
Payment Terms: , T/T
Supply Ability: 100
Delivery Time: 5 working days
Packaging Details: 380mm(L)x550mm(W)x475mm(H)
Product name: Non-dilated Digital Fundus Camera
Focus adjustment range: ±25D
Weight: 26.5Kg
Field View: 50°
Working Distance: 35mm
Minimum Pupil: ≥3.3mm
Shooting light: Auto: with shooting mode
Illumination light: Infrared led
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field

ophthalmic fundus camera SLR camera one-key click 135° wide field


Digital Fundus Camera RetiCam 3100 can be used to capture the anterior and posterior eye images. It has a field of view of 50 degrees for fundus imaging.Digital Fundus Camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.


Field of view50°
Field of view tolerance±7%
Resolution
Center of view≥60 lp/mm
Field of view center (r/2)≥40 lp/mm
At the edge of the field of view (r)≥25 lp/mm
Magnification1.3 times
Required pupil diameter4.0 mm or more (3.3 mm or more when using the small pupil shooting function)
Working distance35 mm
Focus adjustment range±25D
Shooting lightAuto: with shooting mode
Manual: can be set manually
light source
Illumination lightInfrared led
Shooting lightXenon lights
reflected light
Scattered light
cameraDigital camera
Fixing lightInternal fixing light (LED)
External fixation light
Moving range
Stage90 mm left and right, 35 mm front and rear
Main unit moves vertically30 mm
Chin-rest tray movement range60 mm
Rated power supplyAC 100V~240V,50/60Hz
size380 mm(L)x 550 mm(W)x 475 mm(H)

weightAbout 26.5kg
When in maximum light intensity/hole bar state
Spectral wavelength305 nm~1100 nm

Equipment classification
Electric shock protectionClass I device

Degree of electric shock protection


Type B


Water-proof protection


IPX0


Safety level for use in flammable anesthetic gases, oxygen or nitrous oxide mixed with air


Not applicable

Standards

GB 9706.1-2007

IEC 60601-1:1998 + A1:1991 + A2: 1995

Medical electrical equipment - Part 1: General requirements for safety

IEC 60601-1:2005


Medical electrical equipment - Part 1: General requirements for basic safety and practical performance


IEC 60601-1-1:2000


Medical electrical equipment - Part 1-1: General requirements for safety - Parallel standard: Safety requirements for medical electrical systems


IEC 60601-1-2:2001 + A1:2004


Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing


IEC 60601-1-2:2007


Medical electrical equipment – ​​Part 1-2: Basic safety and

General requirements for practical performance – side-by-side standards: electromagnetic compatibility – requirements and testing


IEC 60601-1-4:1996 + A1:1999

Medical Electrical Equipment - Part 1-4: Safety General

Seeking – Parallel Standard: Programmable Medical Electrical System


IEC 60601-1-6:2010


Medical electrical equipment - Part 1-6: General requirements for basic safety and practical performance - Parallel standard: Availability


ISO 14971:2007


Medical Devices – Risk Management for Medical Devices


ISO 15004-1:2006


Ophthalmic instruments - Test methods for basic requirements - Part 1: General requirements for all ophthalmic instruments


ISO 15004-2:2007


Ophthalmic instruments - Test methods for basic requirements - Part 2:


ISO 10940:2009


Ophthalmic Instruments - Fundus Camera


ISO 10993-1:2009 ISO 10993-5:2009 ISO 10993-10:2010


Biological evaluation of medical devices


IEC 62304:2006


Medical Device Software - Software Lifecycle Process


IEC 62366:2007


Medical Devices – Usability Engineering for Medical Devices


GB/T 191-2008


Packaging storage and transportation icon


GB 4824-2013


Industrial, scientific and medical (ism) radio frequency equipment disturbance characteristics limits and methods of measurement


GB/T 14710-2009


Medical electrical environment requirements and test methods


GB/T 16886.1-2011


Medical Device Biology Evaluation - Part 1: Evaluation and Testing in Risk Management Process


GB/T 16886.5-2003


Biological evaluation of medical devices - Part 5: In vitro cytotoxicity test


GB/T 16886.10-2005

Biological evaluation of medical devices - Part 10: Stimulation and delayed hypersensitivity test
GB/T 5702-2003Light source color evaluation method

YY 0634-2008


Ophthalmic instrument fundus camera


YY 0505-2012

Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing



Quality Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field for sale
Send your message to this supplier
 
*From:
*To: Chongqing Bio Newvision Medical Equipment Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0