Sign In | Join Free | My polstate.com |
|
Categories | ECG Machine Parts |
---|---|
Brand Name: | GE |
Model Number: | MAC2000 |
Certification: | CE |
MOQ: | 1pcs |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Delivery Time: | 3-5 working days |
Packaging Details: | Carton |
Product Name: | GE MAC 2000 ECG Analysis System For Repair |
Brand: | GE |
Item No.: | Mac2000 |
Display type: | 7 in. color TFT display with support of minimum 32K colors |
Display resolution: | WVGA resolution – 800 x 480 |
Display data: | Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display |
Height: | 200 mm |
Width: | 390mm |
Weight: | Approx. 5 Kg including battery, without paper |
ECG Interpretation: | Marquette* 12SL ECG Analysis Program for Adults and Pediatrics |
Computerized measurements: | 12-lead analysis |
ECG analysis frequency: | 500 or 1000 samples/second/channel |
Digital sampling rate: | 16000 samples/second/channel for normal data acquisition |
Pace sampling rate: | 75K samples/second/channel |
Company Info. |
China World Technology Medical Equipment Service Group |
Verified Supplier |
View Contact Details |
Product List |
GE MAC 2000 ECG Analysis System For Repair
MAC 2000 ECG Analysis System
The MAC 2000 ECG Analysis System is a portable ECG acquisition, analysis and recording system designed for use by a trained operator in a hospital or medical professional's facility setting, as well as in a clinic, PHiliphhilipysician's office, outreach center or any ECG for testing.
The MAC™ 2000 Electrocardiogram Analysis System is a portable device designed to acquire, analyze, display and record information on adult and pediatric populations in hospitals, medical Professional facilities, clinics, doctor's offices or outreach centers.
notes:
The pediatric population was defined as patients between the ages of 0 and 15 years.
The MAC™2000 ECG Analysis System offers the following modes of operation:
• Resting ECG mode
This mode is the default mode for your system.
• Arrhythmia patterns
This mode is intended to facilitate the automatic creation of documentation.
You can upgrade the basic system with two additional operating modes:
• Exercise mode for exercise stress test (optional)
This mode is used to test PHiliphhilipysical exertion.
• RR analysis mode for RR interval analysis (optional)
This mode is used for RR interval analysis
The basic system prints 6 or 12 EKG derivatives and optionally offers the transmission and reception of EKG data to a central cardiovascular EKG information system. You can also upgrade with software options such as 12-lead ECG measurement and interpretation analysis.
Contraindications
This system is not suitable for use in the following ways:
• During patient transport
• Equipped with high frequency surgical equipment
• As intracardiac application
• As a vital signs PHiliphhilipysiological monitor
ECG Interpretation | Marquette* 12SL ECG Analysis Program for Adults and Pediatrics |
Computerized measurements | 12-lead analysis |
ECG analysis frequency | 500 or 1000 samples/second/channel |
Digital sampling rate | 16000 samples/second/channel for normal data acquisition |
Pace sampling rate | 75K samples/second/channel |
ECG on-screen preview | On-screen preview of acquired 10 second ECG waveform |
Acquisition mode | Provides 10 seconds of instantaneous ECG acquisition |
Dynamic range | AC Differential ±5 mV, DC offset ±300 mV |
Resolution | 4.88 µV +/-1% per LSB @ 500 SPS |
Frequency range | 0.04 to 150 Hz |
Low cut off frequency | 0.04 Hz (ADS off), 0.56 Hz (ADS On) |
High cut off frequency | Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz |
Common mode rejection | >135 dB (with 50/60 Hz filter ON) |
Input impedance | >10MΩ @ 10 Hz |
Lead detection | All disconnected lead detection except RL & RA |
Heart rate meter | 30 to 300 BPM |
Operating system | Microsoft® Windows® CE 6.0 |
Start-up time | Less than 30 seconds |
Display type | 7 in. color TFT display with support of minimum 32K colors |
Display resolution | WVGA resolution – 800 x 480 |
Display data | Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display |
ECG Cables/Leadwires | • IEC/AHA Value 10LD Patient Cable/Leadwire • 10-lead IEC/AHA Patient trunk cable • 14-lead IEC/AHA Patient trunk cable • IEC/AHA (Nst, Nax) Leadwire set (ECG 10-L w/resist, Banana) • IEC/AHA Set of leadwires (4mm connector, 10 leads, defibrillator proof) |
ECG Adapter | IEC/AHA Kit Adapter, 10 set Banana Electrode Prep Pads, CLIP Universal GE 10/Pkg |
Electrodes | • ECG Electrode Clamp (Large, 4/set) • Baby MAC electrodes • Silver Mactrode Plus 1000/CASE • Electrode Application System KISS 10-lead without pump • Electrode Application System KISS 12-lead without pump |
Height | 200 mm |
Width | 390mm |
Depth | 330mm |
Weight | Approx. 5 Kg including battery, without paper |
![]() |